Error 3759 · CNCelite 8058 / 8060 / 8065 / 8070
Message: RPS, contactor control fault, overcurrent on output X12 brake-contactor.
Detection
When starting the RPS manoeuvre with the PWSENAF and PWSENAS marks.
Cause
Over-current at the output of the brake-contactor.
Solution
The possible solutions are:
- Check the X12 connector cable and the power contactor.• Missing 24 Vdc power supply at the X12 connector or is greater than 26 Vdc.
- Contactor damaged.