Error 3753 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: Difference of position greater than MAXDIFREF. Press ENTER + RESET to confirm.

Detection

During CNC startup.

Cause

The absolute coordinate (position value) of the feedback device does not match the one saved during the last CNC session.

Solution

The possible solutions are:

  • Verify that the position of the axis indicated in "Current Coordinate" is correct. If so, press [ENTER] and then [RESET] to clear the error and continue. If the axis position is not correct, there may be an error with the feedback device.
  • If the position that the axis should have is not "Current Coordinate" but "Expected Coordinate”, then clear the error by pressing [ENTER]” and then [RESET]". Then, execute G174 with the position indicated in "Expected Coordinate" and, finally, restart the CNC to recover this position.

·