Error 3739 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: Error in the probe signal during the #GAPCTRL process.

Detection

During execution.

Cause

With the active gap control, the CNC reads a distance greater than the maximum possible (parameter GAPDISTLIMIT). The possible causes are:

  • The probe is not working properly.• The signal received by the CNC is not from the probe (probe connected incorrectly).
  • The probe is incorrectly parameterized (parameters GAPDISTLIMIT and GAPVOLTLIMIT).

Solution

Check the connection and parameterization of the probe. If the error persists, contact your supplier.

·