Error 3611 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: The master spindle of the synchronization is not in the right gear (SYNCSET or CAXSET)
Detection
During execution.
Cause
The master or slave spindle is not in the right gear, parameter SYNCSET or parameter CAXSET if the master spindle is as C axis.
Solution
Change the gear of the master and/or slave spindle in its channel or change the master spindle to the channel of the slave spindle so the gear change is automatic.