Error 3600 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: Zero spindle speed

Detection

During execution.

Cause

No spindle positioning speed has been programmed.

Solution

Check the programming and make sure that parameters REFFEED2 and G00FEED of the active spindle gear are not zero.

·