Error 3068 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: RETRACE completed, deactivate mark to continue
Detection
During execution.
Cause
After ending the execution in retrace mode, the RETRACE mark of the PLC stays active.
Solution
The PLC must cancel the RETRACE mark in order to resume the program.