Error 3063 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: The master spindle of the synchronization goes into closed loop

Detection

During execution.

Cause

The user has programmed an closed-loop synchronization (CLOOP) for the master spindle, but it was working in open loop.

Solution

The CNC informs of the change; no action is required.

·