Error 2557 · CNCelite 8058 / 8060 / 8065 / 8070

Message: #G81: R > I >= Z.

Detection

During block preparation.

Cause

One of these two conditions is not met:

  • R (upper level) > I (level reached in Z without moving in XY).
  • I (level reached in Z without moving in XY) >= Z (depth of drilling).

Solution

Program the R Z I coordinates in such a way as to satis 8058 80608065 8070 fy R > I >= Z.

ꞏ142ꞏ

·