Error 1609 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: Executing a turning cycle requires two axes in the channel
Detection
During execution.
Cause
A lathe cycle has been programmed in a channel with less than two axes or the first axis is not longitudinal (parameter LONGAXIS) or the second one is not a face axis (parameter FACEAXIS).
Solution
Executing lathe cycles requires two axes in the channel.