Error 1519 · CNCelite 8058 / 8060 / 8065 / 8070

Message: NR: M/T/D/H cannot be programmed in the same block

Detection

During execution.

Cause

A repetition blocks (NR) has been programmed in a block that contains an M, T, D or H function.

Solution

Programming block repetition with NR is only valid with blocks that involve a movement. The repetition of other types of blocks must be programmed using flow controlling instructions offered by the CNC.

8058 80608065 8070 ꞏ69ꞏ

The same code on other products

·