Error 1245 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: G96: no face axis (FACEAXIS) has been defined in the active plane
Detection
During execution.
Cause
None of the axes of the plane has been defined as face axis.
Solution
Define one of the axes of the main plane as face axis (parameter FACEAXIS).