Error 0174 · CNCelite 8058 / 8060 / 8065 / 8070
Message: Rotary axes, it is not required to complete a full turn.
Detection
During the validation of the machine parameters.
Cause
The CNC cannot activate the volumetric compensation because there is more than one rotary axis module between the moving axes (MOVAXIS parameter), and the travel of the second axis is not complete (0 to 360º).
Solution
Define the modulus of the second rotary axis between 0 and 360° and validate the volumetric compensation.