Error 2037 · CNC 8055 M
Message: 24 V missing at the CPU-CNC module.
Detection
During execution.
Effect
It stops the movement of the axes and the spindle, eliminating all the enable signals and canceling all the analog outputs of the CNC. When detected from the position loop, it opens the position loop and sets the LOPEN mark to ·1·.
If it is in execution, it interrupts the execution of the part program of the CNC of its channel.
Besides this, it activates the external emergency output.
Cause
At a modular CNC 8055: 24 V missing at the CPU module of the CNC. The fuse may be blown.
At a CNC 8055i: 24V missing at CNC connector X2. The fuse may be blown.
Solution
At a modular CNC 8055: Apply voltage to the CPU module of the CNC (24 V). If the fuse is blown, replace it.