Error 0183 · CNC 8055 M
Message: Cycle does not exist.
Detection
While editing at the CNC or while executing a program transmitted via DNC.
Cause
In the "DIGIT" instruction, a digitizing cycle has been defined which is not available.
Solution
The "DIGIT" instruction only admits two types of digitizing:
(DIGIT 1,…) : Grid pattern digitizing cycle.
(DIGIT 2,…) : Arc pattern digitizing cycle.