Error 0183 · CNC 8055 M

Message: Cycle does not exist.

Detection

While editing at the CNC or while executing a program transmitted via DNC.

Cause

In the "DIGIT" instruction, a digitizing cycle has been defined which is not available.

Solution

The "DIGIT" instruction only admits two types of digitizing:

(DIGIT 1,…) : Grid pattern digitizing cycle.