Error 4034 · CNC 8055 M · CNC 8055 T
Message: SID reading error
Detection
During the operation of the CAN bus.
Effect
It stops the movement of the axes and the spindle, eliminating all the enable signals and canceling all the analog outputs of the CNC. When detected from the position loop, it opens the position loop and sets the LOPEN mark to ·1·.
If it is in execution, it interrupts the execution of the part program of the CNC of all channels.
Besides this, it activates the external emergency output.
Cause
From a CNC channel, an attempt has been made to read a non-existent variable of the drive.
Solution
Check that the variable that it is trying to read exists at the drive.