Error 1003 · CNC 8055 M · CNC 8055 T

Message: Rounding in last block.

Detection

During execution.

Cause

A "Controlled rounding radius (G36) or "Chamfer (G39) has been defined on the last path of the program or when the CNC does not find information about the path following the definition of the rounding or chamfer.

Solution

A rounding or chamfer must be defined between two paths.

·