Error 0207 · CNC 8055 M · CNC 8055 T

Message: Complete Table.

Detection

While editing tables.

Cause

In the tables for "M" functions or tool offsets, an attempt has been made to define more data than those allowed by the manufacturer by means of machine parameters. When loading a table via DNC, the CNC does not delete the previous table, it replaces the existing values and it copies the new data in the free positions of the table.

Solution

The maximum number of data that can be defined is limited by the machine parameters:

To load a new table via DNC, the previous table should be deleted.

·