Error 0094 · CNC 8055 M · CNC 8055 T
Message: ASIN/ACOS range exceeded.
Detection
While editing at the CNC or while executing a program transmitted via DNC.
Cause
An operation has been programmed which involves calculating the arcsine or arccosine of a number out of the ±1 range.
Solution
Only the arc sine (ASIN) or the arc cosine (ACOS) of numbers between ±1 can be calculated. When working with parameters, that parameter may have alreadyacquired a value out of the mentioned values. Verify that the parameter does not reach the operation with that value (0).