Error 0070 · CNC 8055 M · CNC 8055 T

Message: Program already exists.

Detection

In execution or while executing programs transmitted via DNC.

Cause

This error comes up during execution when using the "OPEN" instruction (While programming in high level language) to create an already existing program.

Solution

Change the program number or use parameters A/D in the "OPEN" instruction:

(OPEN P.........,A/D,… )

Where:

A: Appends new blocks after the existing ones.

D: Deletes the existing program and it opens it as a new one.