Error 0010 · CNC 8055 M · CNC 8055 T
Message: No more M functions allowed
Detection
While editing at the CNC or while executing a program transmitted via DNC.
Cause
More than 7 "M" functions have been programmed in a block.
Solution
The CNC does not let program more than 7 "M" functions in a block. To execute any other functions, write them in a separate block. The "M" functions may go alone in a block.