Error 6000 · CNC 8058 / 8060 / 8065 · CNC 8070

Message: Feedback alarm

Detection

During execution.

Cause

Feedback alarm on an analog axis (parameter FBACKAL).

For differential TTL signal.

  • One or more cables broken (A, B signals or their inverted signals).
  • Feedback input disconnected at the counter.

For differential sinusoidal signal.

  • One or more cables broken (A, B signals or their inverted signals).
  • Feedback input disconnected at the counter.
  • Input signal amplitude above 1.45 Vpp (approximately).
  • Input signal amplitude under 0.4 Vpp (approximately).• Too much phase shift between A and B signals (in quadrature, in theory)

For non-differential signals, the feedback alarm must be disabled.

Solution

Check the cables and the connection of the feedback inputs. If the error persists, contact the Service Department.

The same code on other products

·