Error 6000 · CNC 8058 / 8060 / 8065 · CNC 8070
Message: Feedback alarm
Detection
During execution.
Cause
Feedback alarm on an analog axis (parameter FBACKAL).
For differential TTL signal.
- One or more cables broken (A, B signals or their inverted signals).
- Feedback input disconnected at the counter.
For differential sinusoidal signal.
- One or more cables broken (A, B signals or their inverted signals).
- Feedback input disconnected at the counter.
- Input signal amplitude above 1.45 Vpp (approximately).
- Input signal amplitude under 0.4 Vpp (approximately).• Too much phase shift between A and B signals (in quadrature, in theory)
For non-differential signals, the feedback alarm must be disabled.
Solution
Check the cables and the connection of the feedback inputs. If the error persists, contact the Service Department.