Error 0056 · CNC 8058 / 8060 / 8065 · CNC 8070

Message: Compensation table positions not in ascending order

Detection

During the validation of the machine parameters.

Cause

In the compensation tables, the points to be compensated are not ordered correctly or the value to compensate in all the points have a zero value.

Solution

The POSITION parameter within the compensation tables must have ascending values. The value to compensate cannot be zero in all the points.

The same code on other products

·