Error 0046 · CNC 8058 / 8060 / 8065 · CNC 8070
Message: Nonexistent axis
Detection
During the validation of the machine parameters.
Cause
The possible causes are:
- The user has assigned the name of an axis that does not exist to a machine parameter.
- Either the VMOVAXIS or VCOMPAXIS axis is undefined in the basic volumetric compensation.
Solution
Correct the machine parameters. The valid axis names are the ones defined in parameter AXISNAME.